Update firmware and config server paths in XML
These two values state Mandatory in the template so added a default value - grandstream_dial_timeout - grandstream_web_access_mode
This commit is contained in:
@@ -83,11 +83,21 @@
|
||||
|
||||
<!-- # Firmware Server Path -->
|
||||
<!-- # Server address -->
|
||||
<P192>{$grandstream_firmware_path}/ht814/</P192>
|
||||
<P192>{$grandstream_firmware_path}/ht814/{$firmware_version}</P192>
|
||||
{elseif isset($grandstream_firmware_path)}
|
||||
<P192>{$grandstream_firmware_path}/ht814</P192>
|
||||
{else}
|
||||
<P192>{$domain_name}{$project_path}/app/provision</P192>
|
||||
|
||||
<!-- # Config Server Path -->
|
||||
<!-- # Server address; -->
|
||||
{if $grandstream_config_server_path=="none"}
|
||||
<P237></P237>
|
||||
{elseif isset($grandstream_config_server_path)}
|
||||
<P237>{$grandstream_config_server_path}</P237>
|
||||
{elseif isset($domain_name)}
|
||||
<P237>{$domain_name}{$project_path}/app/provision</P237>
|
||||
{/if}
|
||||
|
||||
<!-- # XML Config File Password -->
|
||||
<!-- # String; between ascii values 33 and 126 -->
|
||||
@@ -945,7 +955,11 @@
|
||||
<!-- # No Key Entry Timeout. Default - 4 seconds. -->
|
||||
<!-- # Number: 1-15 -->
|
||||
<!-- # Mandatory -->
|
||||
{if isset($grandstream_dial_timeout) }
|
||||
<P85>{$grandstream_dial_timeout}</P85>
|
||||
{else}
|
||||
<P85>4</P85>
|
||||
{/if}
|
||||
|
||||
<!-- # Early Dial. 0 - No, 1 - Yes (use "Yes" only if proxy supports 484 response) -->
|
||||
<!-- # Number: 0, 1 -->
|
||||
@@ -1575,7 +1589,11 @@
|
||||
<!-- # Web Access Mode. 0 - HTTPS, 1 - HTTP. -->
|
||||
<!-- # Number: 0, 1 -->
|
||||
<!-- # Mandatory -->
|
||||
{if isset($grandstream_web_access_mode) }
|
||||
<P1650>{$grandstream_web_access_mode}</P1650>
|
||||
{else}
|
||||
<P1650>0</P1650>
|
||||
{/if}
|
||||
|
||||
<!-- # HTTP Web Port. Default HTTP is 80. -->
|
||||
<!-- # Number: 1 to 65535 -->
|
||||
|
||||
Reference in New Issue